1. Periodically measure the process parameters of the bag filter, such as flue gas volume, temperature, concentration, etc. If abnormality is found, the cause should be found and dealt with in time.
2. Using a timed cleaning controller, it should be regularly determined whether the cleaning cycle is accurate. Regularly check the working condition of the pressure switch, check whether the pressure port is blocked, and clean it.
3. If the electromagnetic pulse valve malfunctions, it should be eliminated in time. If there are impurities or moisture inside, it should be cleaned. If the diaphragm is damaged, it should be replaced in time.
4. The management personnel should be familiar with the principle, performance and use conditions of the bag filter, and master the adjustment and maintenance methods.
5. When the bag dust collector is turned on, it should first connect compressed air to the air storage tank, connect the control power supply, and start the ash discharge device. If there are other equipment in the system, the downstream equipment should be started first.
6. The mechanical moving parts such as the bag deduster reducer and ash conveying device should be filled with oil and changed according to the regulations. If any abnormal phenomenon is found, it should be eliminated in time.